20200803054614115

IPSCAPC Cable Assemblies Specification

IPSCAPC Cable Assemblies Specification

INFORMATION

Application

●    Fiber
optic communications in harsh outdoor environments Outdoor communication
equipment connection

●    waterproof
fiber equipment SC port Remote wireless base station

●    FTTx wiring
project

 

Features

●    Cost
effective solution for in house termination. 

●    Low insertion loss and added
loss.

●   Height of attenuation.

●    IP67 water, dust
proof and corrosion resistant

●   The material in the jumpel cable
are all-weather and UV-resistant. 6.Mechanical performance: IEC 61754-4
standard.

●    RoHS
and REACH materials compliant. 8.Cable diameter Range: 5.0mm to 4.0* 7.0mm.

 


Cable
Structure

End-Face Geometry

 

Item

UPC
(Ref: IEC 61755-3-1)

APC
(Ref: IEC 61755-3-2)

Radius of curvature (mm)

10 to 25

5
to 12

Fiber height (nm)

-100 to 100

-100
to 100

Apex offset (μm)

0
to 50

0
to 50

APC angle (°)

/


±0.2°

Key error (°)

/

0.2°
max



 End-Face Qualty
(SM)

 

Zone

Range (μm)

Scratches

Defects

Reference

A: Core

0 to 25

None

None

 

 

 

 

IEC 61300-3-35:2015

B: Cladding

25 to 115

None

None

C: Adhesive

115 to 135

None

None

D: Contact

135 to 250

None

None

E: Rest of ferrule

None

None

 

End-Face
Qualty (MM)

 

Zone

Range (μm)

Scratches

Defects

Reference

A: Core

0 to 65

None

None

 

 

 

 

 

IEC 61300-3-35:2015

B: Cladding

65 to 115

None

None

C: Adhesive

115 to 135

None

None

D: Contact

135 to 250

None

None

E: Rest of ferrule

None

None

 

Mechanical
Characteristics

 

Test

Conditions

Reference

Endurance

500 matings

IEC 61300-2-2

Vibration

Frequency: 10 to 55Hz,
Amplitude: 0.75mm

IEC 61300-2-1

Cable retention

100N (main cable); 50N
(connector part)

IEC 61300-2-4

Strength of coupling
mechanism

80N for 2 to 3mm cable

IEC 61300-2-6

Cable torsion

15N for 2 to 3mm cable

IEC 61300-2-5

Fall

10 drops, 1m drop height

IEC 61300-2-12

Static lateral load

1N for 1h (main cable);
0.2N for 5min (ranch part)

IEC 61300-2-42

Cold

-25°C, 96h duration

IEC 61300-2-17

Dry heat

+70°C, 96h duration

IEC 61300-2-18

Change of temperature

-25°C to +70°C, 12 cycles

IEC 61300-2-22

Humidity

+40°C at 93%, 96h duration

IEC 61300-2-19