IPSCAPC Cable Assemblies Specification
IPSCAPC Cable Assemblies Specification
INFORMATION
Application
● Fiber
optic communications in harsh outdoor environments Outdoor communication
equipment connection
● waterproof
fiber equipment SC port Remote wireless base station
● FTTx wiring
project
Features
● Cost
effective solution for in house termination.
● Low insertion loss and added
loss.
● Height of attenuation.
● IP67 water, dust
proof and corrosion resistant
● The material in the jumpel cable
are all-weather and UV-resistant. 6.Mechanical performance: IEC 61754-4
standard.
● RoHS
and REACH materials compliant. 8.Cable diameter Range: 5.0mm to 4.0* 7.0mm.
Cable
Structure
|
End-Face Geometry
|
Item |
UPC |
APC |
|
Radius of curvature (mm) |
10 to 25 |
5 |
|
Fiber height (nm) |
-100 to 100 |
-100 |
|
Apex offset (μm) |
0 |
0 |
|
APC angle (°) |
/ |
8° |
|
Key error (°) |
/ |
0.2° |
(SM)
|
Zone |
Range (μm) |
Scratches |
Defects |
Reference |
|
A: Core |
0 to 25 |
None |
None |
IEC 61300-3-35:2015 |
|
B: Cladding |
25 to 115 |
None |
None |
|
|
C: Adhesive |
115 to 135 |
None |
None |
|
|
D: Contact |
135 to 250 |
None |
None |
|
|
E: Rest of ferrule |
None |
None |
||
End-Face
Qualty (MM)
|
Zone |
Range (μm) |
Scratches |
Defects |
Reference |
|
A: Core |
0 to 65 |
None |
None |
IEC 61300-3-35:2015 |
|
B: Cladding |
65 to 115 |
None |
None |
|
|
C: Adhesive |
115 to 135 |
None |
None |
|
|
D: Contact |
135 to 250 |
None |
None |
|
|
E: Rest of ferrule |
None |
None |
||
Mechanical
Characteristics
|
Test |
Conditions |
Reference |
|
Endurance |
500 matings |
IEC 61300-2-2 |
|
Vibration |
Frequency: 10 to 55Hz, |
IEC 61300-2-1 |
|
Cable retention |
100N (main cable); 50N |
IEC 61300-2-4 |
|
Strength of coupling |
80N for 2 to 3mm cable |
IEC 61300-2-6 |
|
Cable torsion |
15N for 2 to 3mm cable |
IEC 61300-2-5 |
|
Fall |
10 drops, 1m drop height |
IEC 61300-2-12 |
|
Static lateral load |
1N for 1h (main cable); |
IEC 61300-2-42 |
|
Cold |
-25°C, 96h duration |
IEC 61300-2-17 |
|
Dry heat |
+70°C, 96h duration |
IEC 61300-2-18 |
|
Change of temperature |
-25°C to +70°C, 12 cycles |
IEC 61300-2-22 |
|
Humidity |
+40°C at 93%, 96h duration |
IEC 61300-2-19 |
Related Products
Send an Inquiry
Tell us your required quantity, destination country, and any technical requirements. We'll reply within 12 hours.